Página 3 - FCC Information

1189Chapter 11111IntroductionThe Altusen 16-port LCD Console KVM switch offers a highly efficientnetwork management solution. Specially designed high-

Página 4 - Table of Contents

12Features10The main features of the KL0116 unit are as follows:• A single LCD console drawer with built-in KVM switch controls up to 16 computers d

Página 5 - Chapter 6

1311BenefitsThe KL0116 KVM switch saves time and money by allowing a singleconsole to manage each connected computer. Installing the KL0116provides th

Página 6 - About this Manual

1412Hardware RequirementsComputers To use and access the KL0116 successfully, your computer requires the following:

Página 7 - Special Message Conventions

1513KL0116 Front View1. Handle • Pull the handle to slide the KVM module out. Push to slide the module in.2. LCD Screen • After sliding the

Página 8 - Additional Help

1614KL0116 Front View cont.7. Touchpad8. LCD Display Controls NOTE: See the LCD Display Quick Reference Guide (provided with this package) for d

Página 9

1715KL0116 Back View1. Power Switch • Turn on the KL0116 with the standard rocker power switch.2. Power Socket • Plug the AC power cord

Página 10

18Before you begin, turn off power to all devices with which you plan to connect.To prevent damage to your equipment due to static electric discharge,

Página 11 - Introduction

19NOTE: For more information on the relationship between the number of both computersand KL0116 units needed to control each computer, see page 46 in

Página 13 - Package Contents

20Hot PluggingThe KL0116 supports hot plugging: You can remove or add components to theinstallation by unplugging their cables from the ports without

Página 14 - Hardware Requirements

21Port ID NumberingEach CPU port on a KL0116 installation has a unique assigned Port ID. The Port IDincludes two parts: a Station Number and a Port Nu

Página 15 - KL0116 Front View

22Chapter 33333Hot Key OperationHot Keys allow you to use keyboard sequences that perform a variety of actionsfor KL0116 operations. This chapter prov

Página 16 - KL0116 Front View cont

23• The screen displays a command line prompt with the word Hot Keys in yellow text on a blue background as well as all subsequent keyed in Hot

Página 17 - KL0116 Back View

24automatically monitor their activity. (See Scan/Skip Mode of the OSD F3SET function).Setting the Scan IntervalSet the amount of time Auto Scan waits

Página 18 - Installation

25 rather than Exit Auto Scan mode. With this method, you start from where you left off once scanning resumes. On the other hand, scanning begins

Página 19

261. Activate Hot Key Mode (see page 20).2. Press [B]The Beeper toggles On or Off. The command line displays Beeper On orBeeper Off for one second a

Página 20 - Powering Off and Restarting

27Chapter 44444OSD OperationThe KL0116 On-Screen Display (OSD) provides a visual interface that controlscomputer and switching operations from your de

Página 21 - Port Selection

28NOTE: 1. The above figure shows the Administrator’s Main Menu. The F4 and F6 functions are reserved for the Administrator and do not display

Página 22 - Hot Key Operation

29OSD FunctionsThe OSD provides a series of function keys used to configure and controlvarious computer operations. For example, you can rapidly switc

Página 23 - Auto Scanning

3FCC InformationThis is an FCC Class A product. In a domestic environment, this product may causeradio interference in which case the user may be re

Página 24 - Activating Auto Scan:

30F1 GOTO:To activate the GOTO function, press [F1] or click the F1 menu optionlocated at the top of the Main Menu screen.GOTO allows you to switch di

Página 25 - Hot Key Beeper Control

31LIST allows you to broaden or narrow the scope of ports listed on theOSD.To activate a submenu option, move the highlight bar to the desired optiona

Página 26 - Hot Key Summary Table

32SET allows an Administrator or User to set up a unique workingenvironment profile. The stored profile activates each time a correspondinguser logs i

Página 27 - OSD Operation

33( continued from previous page )F4 ADM:To activate the ADM function, press [F4] or click the F4 menu optionlocated at the top of the Main Menu scree

Página 28 - OSD Main Menu Headings

34noitpOniaMnoitpircseDDROWSSAPDNAEMANRESUTES dnarotartsinimda)1(rofsdrowssapdnaemanresusteS:wolebdebircsedsasresu)4(,sdleifresurorotartsinimdaehtreht

Página 29 - OSD Functions

3516( continued from previous page)noitpOniaMnoitpircseDSEMANTROPTIDE ylisaeottrophcaeotemaneuqinuangissanacuoYehT.retupmocgnidnopserrocs'tropaez

Página 30 - F2 LIST:

36In case the administrator forgets the correct combination of the user name andpassword, do the following to restore the default user name and passwo

Página 31

37Please make sure this documentation and the KVM switches are placedseparately and all in secured locations to avoid security breaches.F5 SKP:To acti

Página 32

38The BRC function is especially useful for performing operations onmultiple computers, such as a system-wide shutdown or upgradingsoftware. For insta

Página 33

39 assigned scan duration time.• The letter S appears in to the left of the Port ID display, indicating that it is being accessed under Auto Sca

Página 34

4 About this Manual ...How this manual is organized ...

Página 36

41Chapter 55555The Firmware Upgrade UtilityThe Windows Firmware Upgrade Utility provides an automated method to easilyupgrade the KL0116 firmware. Thi

Página 37

42NOTE: For a daisy-chain installation, connect the cable to the first KVM station. The subsequent KVM stations in the chain receive the up

Página 38 - F7 SCAN:

433. Select the KVM device and then click OK.4. As you select KVM devices, a detailed description of each appears in the Device Description pane.5.

Página 39 - F8 LOUT:

44• If you didn’t enable Check Firmware Version, the Utility installs the upgrade files without comparing the device version with that of the u

Página 40

45Click Cancel to close the Firmware Upgrade Utility.43

Página 42 - Starting the Upgrade

47Chapter 66666Control KL0116 RemotelyThe Altusen LCD Console KVM Switch can be controlled remotely by using theRemote Console Port and the Remote Con

Página 43

48KL0116 Connection TableIt is redundant and expensive to use additional KL0116 built-in console switchesfor daisy chaining. Instead, use KH0116 switc

Página 44 - Upgrade Failed

49OSD Factory Default SettingsThe factory default settings are as follows:gnitteStluafeDyektoHDSO]kcoLllorcS[]kcoLllorcS[noitisoPyalpsiDDItroPrenroctf

Página 45

5Chapter 4OSD Operation ...OSD overview...

Página 46

50Specifications( continued)noitcnuFnoitacificepSsnoitcennoCretupmoCgnidacsaCroniahCysiaD215tceriD61elosnoCsrotcennoCedargpUMORhsalF11JRx1lortnoCetome

Página 47 - Control KL0116 Remotely

51( continued from previous page)noitcnuFnoitacificepShctiwSteseRnottubhsupdessecer-imeSx1egatloVgnisnes-otuAV022-011noituloseRoediVDCLTFT"51;867

Página 48 - KL0116 Connection Table

52Clear Login InformationIf you are unable to perform an Administrator login for any reason (i.e. corruptedor forgotten username and password), follow

Página 49 - OSD Factory Default Settings

53513. Unscrew the thumb screws and unplug the data cable.Removing the KVM ModuleYou can conveniently remove the KVM module from the unit chassis for

Página 50 - Specifications

54LCD OSD Quick Reference52Removing the Keyboard and TouchpadYou can easily remove the keyboard and touchpad for repair or maintenance.Follow these st

Página 51

5555LCD Display Quick ReferenceThe LCD Display allows you to set up and configure the LCD display parameters: • To bring up the LCD Display main

Página 52 - Clear Login Information

56Rack MountingThe KL0116 can be mounted in a 1U system rack. For convenience andflexibility, a rack mounting kit that allows several mounting options

Página 53 - Removing the KVM Module

5755Note: Be sure to leave a 13mm gap between the flange and the rear of the chassis inorder to have enough room to screw the tab to the flange (see s

Página 54 - LCD OSD Quick Reference

58Limited WarrantyAltusen warrants this product against defect in material or workmanship for a period ofthree (3) years from the date of purchase. I

Página 55 - LCD Display Quick Reference

59IndexAActivate Beeper ...ADM ...Administrator function

Página 56 - Rack Mounting

6About this ManualWelcome to the 16-Port LCD Console KVM Switch (KL0116) User Manual,which provides information for understanding and using the Altus

Página 58 - Limited Warranty

7Document ConventionsThis manual uses a variety of formats to identify different types of information,reiruocretupmocneercs-no,stnemetatsxatnyssahcusn

Página 59

8Additional HelpAltusen provides the following support options for additional help, adviceand information:6troppuSlacinhceTNESUTLAlacinhceTaciremAhtro

Página 60

9Please have the following information ready before contacting Altusentechnical support:• Product model number, serial number and date of purchase.• Y